Skip to content

EPA 608 Technician Certification Small Appliance Recovery Rules Summary

Checked 11/1/26

Small Appliance Recovery Rules: key points

  • Small appliance = factory-sealed with 5 pounds of refrigerant or less.
  • Newer equipment and a working compressor: recover 90 percent; otherwise 80 percent.
Importance
★★★★★ (5 / 5)
Weight
About 13 of 25 Type I (Small Appliances) questions (50%)

What counts as a small appliance, the 80 and 90 percent recovery requirements, the 4-inch vacuum option, certified recovery equipment, Type I test formats, and safe disposal by the final processor.

📖 See more Small Appliance Recovery Rules concepts →

Small Appliance Recovery Rules: 10 sample questions

Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 1. Under EPA rules, what is a "small appliance"?

  1. ① A field-assembled split system with 15 pounds or less
  2. ② Any appliance with less than 50 pounds of refrigerant
  3. ③ A factory-built, factory-charged, hermetically sealed appliance with 5 pounds of refrigerant or less
  4. ④ Any appliance that plugs into a wall outlet
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ③ A factory-built, factory-charged, hermetically sealed appliance with 5 pounds of refrigerant or less

Key point: Small appliance: factory-sealed, 5 lb or less

40 CFR 82.152 defines a small appliance as one that is fully manufactured, charged, and hermetically sealed in a factory with 5 pounds or less of refrigerant, such as household refrigerators, window air conditioners, dehumidifiers, and water coolers.

Wrong choices

  • A field-assembled split system with 15 pounds or less: Field-assembled systems are not small appliances, and the limit is 5 pounds, not 15.
  • Any appliance with less than 50 pounds of refrigerant: 50 pounds is a leak repair threshold, not the small appliance limit.
  • Any appliance that plugs into a wall outlet: Plugging into an outlet does not make an appliance "small" under the rule.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 2. Which of these is a small appliance under EPA rules?

  1. ① A window air conditioner
  2. ② A 3-ton split-system central air conditioner
  3. ③ A packaged rooftop unit
  4. ④ A centrifugal chiller
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ① A window air conditioner

Key point: Window AC, fridge, dehumidifier = small appliances

Small appliances include window and room air conditioners, household refrigerators and freezers, dehumidifiers, under-counter ice makers, vending machines, and drinking water coolers, as long as they are factory-sealed with 5 pounds or less.

Wrong choices

  • A 3-ton split-system central air conditioner: A split system is assembled and charged in the field, so it is not a small appliance.
  • A packaged rooftop unit: Rooftop units usually hold more than 5 pounds and need Type II.
  • A centrifugal chiller: Chillers are large appliances (Type II or Type III).
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 3. A technician uses recovery equipment made after November 15, 1993, on a small appliance whose compressor works. How much refrigerant must be recovered?

  1. ① 80 percent
  2. ② 90 percent
  3. ③ 100 percent
  4. ④ 70 percent
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ② 90 percent

Key point: New equipment + working compressor = 90%

Under 40 CFR 82.156(b), with recovery equipment made on or after November 15, 1993, recover 90 percent of the refrigerant if the appliance's compressor works, or 80 percent if it does not. Evacuating to 4 inches of mercury vacuum also meets the rule.

Wrong choices

  • 80 percent: 80 percent applies when the compressor does not work or the equipment is older.
  • 100 percent: EPA does not require 100 percent recovery.
  • 70 percent: 70 percent is not a recovery requirement.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 4. Using recovery equipment made after November 15, 1993, a technician works on a small appliance whose compressor does NOT run. How much refrigerant must be recovered?

  1. ① 90 percent
  2. ② 50 percent
  3. ③ 75 percent
  4. ④ 80 percent
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ④ 80 percent

Key point: Compressor not working = 80%

When the small appliance's compressor is not working, the requirement is 80 percent recovery, even with newer equipment. Without a working compressor it is harder to push refrigerant out of the system.

Wrong choices

  • 90 percent: 90 percent applies only when the compressor works.
  • 50 percent: 50 percent is far too low.
  • 75 percent: 75 percent is not a recovery requirement.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 5. Which certification type is needed to service small appliances such as household refrigerators?

  1. ① Type I (or Universal)
  2. ② No certification is needed
  3. ③ Type II
  4. ④ Type III
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ① Type I (or Universal)

Key point: Small appliances = Type I

Under 40 CFR 82.161(a)(1)(i), people who maintain, service, or repair small appliances must be certified as Type I technicians (Universal also covers them).

Wrong choices

  • No certification is needed: Servicing that opens the refrigerant circuit requires certification.
  • Type II: Type II is for high- and medium-pressure appliances other than small appliances.
  • Type III: Type III is for low-pressure appliances.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 6. A technician uses recovery equipment made BEFORE November 15, 1993, on a small appliance. How much refrigerant must be recovered?

  1. ① 80 percent, whether or not the compressor works
  2. ② 70 percent
  3. ③ 90 percent if the compressor works
  4. ④ No set amount for older equipment
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ① 80 percent, whether or not the compressor works

Key point: Pre-1993 equipment = 80% always

For recovery equipment made before November 15, 1993, the rule is 80 percent recovery from a small appliance, no matter whether the compressor runs.

Wrong choices

  • 70 percent: 70 percent is not a recovery requirement.
  • 90 percent if the compressor works: The 90 percent rule applies only to equipment made on or after November 15, 1993.
  • No set amount for older equipment: Older equipment still has a set requirement.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★★

Question 7. Instead of measuring a percentage, how else can a technician meet the small appliance recovery requirement?

  1. ① Evacuate the appliance to 10 inches of mercury vacuum
  2. ② Evacuate the appliance to 4 inches of mercury vacuum
  3. ③ Evacuate the appliance to 25 mm Hg absolute
  4. ④ Evacuate the appliance to 0 psig
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ② Evacuate the appliance to 4 inches of mercury vacuum

Key point: Small appliances: or pull to 4 in. Hg vacuum

40 CFR 82.156(b)(3) lets technicians meet the small appliance rule by evacuating to four inches of mercury vacuum instead of proving 80 or 90 percent recovery.

Wrong choices

  • Evacuate the appliance to 10 inches of mercury vacuum: 10 inches applies to some larger high- and medium-pressure appliances.
  • Evacuate the appliance to 25 mm Hg absolute: 25 mm Hg absolute applies to low-pressure appliances.
  • Evacuate the appliance to 0 psig: 0 psig is not enough for small appliance recovery.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★☆

Question 8. A technician passed an open-book (mail-in) Type I test. Can that test be used toward Universal certification?

  1. ① Yes, if the Core section was also open-book
  2. ② Yes, if passed with at least 70 percent
  3. ③ Yes, after one year of experience
  4. ④ No; Universal requires closed-book, proctored testing
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ④ No; Universal requires closed-book, proctored testing

Key point: Open-book Type I cannot count toward Universal

EPA rules say mail-in Type I tests cannot be used toward Universal, and EPA notes that a Core test taken open-book cannot be used for Universal either. Universal requires closed-book, proctored tests.

Wrong choices

  • Yes, if the Core section was also open-book: EPA says open-book Core tests cannot be used for Universal either.
  • Yes, if passed with at least 70 percent: The score does not change the rule for open-book tests.
  • Yes, after one year of experience: Experience does not change the rule.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★☆

Question 9. What must every small appliance (other than those using only exempt refrigerants) have so refrigerant can be removed?

  1. ① A process stub
  2. ② A sight glass
  3. ③ A permanent service valve on both sides
  4. ④ A pump-out unit
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ① A process stub

Key point: Small appliances must have a process stub

40 CFR 82.154(e) says small appliances must be sold with a process stub, a short length of tubing that gives access to the refrigerant and can be resealed after service.

Wrong choices

  • A sight glass: A sight glass is not required for recovery.
  • A permanent service valve on both sides: Permanent service valves are not required on small appliances.
  • A pump-out unit: Pump-out units are used on some large appliances.
Practice questionReviewedType I (Small Appliances) › Small Appliance Recovery Rules★★★★☆

Question 10. A person is dismantling old refrigerators for scrap. Under EPA rules, does that person need Section 608 certification just to dispose of them?

  1. ① Yes, Type II certification is required
  2. ② No, but the refrigerant must still be properly recovered before disposal
  3. ③ Yes, Type I certification is required
  4. ④ No, and the refrigerant may be vented
▼ Show answer and explanation▲ Hide answer and explanation

Answer: ② No, but the refrigerant must still be properly recovered before disposal

Key point: Disposal of small appliances: no cert, but recover

40 CFR 82.161(a)(1)(vii) says people who dispose of small appliances are not required to be certified. However, the refrigerant must still be recovered to the 80/90 percent or 4-inch vacuum levels using certified equipment.

Wrong choices

  • Yes, Type II certification is required: Type II does not apply to small appliances.
  • Yes, Type I certification is required: Certification is not required for disposal of small appliances, though recovery is still required.
  • No, and the refrigerant may be vented: Venting is never allowed.

Test yourself.

Written by AI · Not yet reviewed by staff